Since the "Fix" for the motor bug, another bug is present, the time-out is broken if the first transponder it tries to scan is inactive.

When you do first do a manual scan of a Single Satellite, if the first transponder it tries to scan is inactive it will sit there forever.
I currently get around this by manually tuning a known "Active" transponder on the satellite I wish to scan, it will then lock, return to manual scan and select single satellite and it will then start scanning.

You are also unable to do a Automatic scan, as if the dish moves to a position where the first transponder it tries to scan is inactive it will stay there.

This is present on ALL OA-E Images not just ViX and present on all boxes that have had the latest commit.